超高效液相色谱法测定口腔护理产品中异噻唑啉酮类含量

宋青梅1,*(),杜丰2   

  1. 1.濮阳医学高等专科学校,河南 濮阳 457000
    2.濮阳市人民医院,河南 濮阳 457000
  • 收稿日期:2023-04-24 修回日期:2023-09-06 出版日期:2023-09-22 发布日期:2023-09-26

Determination of thiazolidinones in oral care products by ultra performance liquid chromatography

Song Qingmei1,*(),Du Feng2   

  1. 1. Puyang Medical College, Puyang, Henan 457000, China
    2. Puyang Peaple's Hospital, Puyang, Henan 457000, China
  • Received:2023-04-24 Revised:2023-09-06 Online:2023-09-22 Published:2023-09-26
  • Contact: * Tel.: +86-13939338111, E-mail: 154452708@qq.com.

摘要:

采用超高效液相色谱法测定口腔护理产品中异噻唑啉酮类含量。通过HyperSep反相C8/苯磺酸离子交换器(HyperSep C8/BSAIE),Sep-Pak C18吸附剂的固相萃取(SPE)及超高效液相色谱/二极管阵列检测器(UPLC/DAD)用于同时测定口腔护理产品中甲基异噻唑啉酮(MI)和甲基氯异噻唑啉酮(MCI)。结果发现,HyperSep C8/BSAIE和UPLC/DAD的洗脱溶剂为混合物(乙腈和甲醇体积比2:1),较佳检测波长为255 nm;该方法具有良好的线性范围(0.005~10 µg/mL),测定系数(R2,0.997~0.999),检测限(LOD,0.001~0.002 µg/g);在检测低(0.07 µg/mL)、中(3 µg/mL)和高(15 µg/mL)质量浓度的标准混合物时,相对标准偏差RSD<3%。共研究了12个口腔护理样品,MI含量为nd~0.89 µg/g,MCI含量为nd~0.62 µg/g。根据样品的类型,回收率在95.33%~101.43%之间。

关键词: 异噻唑啉酮, 对羟基苯甲酸酯, 化妆品, 固相萃取, 超高效液相色谱

Abstract:

The purpose of this paper is to determine the content of isothiazolinones in oral care products by ultra performance liquid chromatography. A HyperSep reversed-phase C8/BSAIE ion exchanger, solid phase extraction (SPE) with Sep-Pak C18 sorbent and an ultra performance liquid chromatography/diode array detector (UPLC/DAD) were used for the simultaneous determination of methylisothiazolinone (MI) and methylchloroisothiazolinone (MCI) in oral care products. The results find that the eluting solvents for HyperSep C8/BSAIE and UPLC/DAD are mixtures (acetonitrile/methanol, volume ratio 2:1) with an optimum detection wavelength of 255 nm. The method has a good linear range (0.005-10 µg/mL), the coefficient of determination (R2) ranges from 0.997 to 0.999, and the limit of detection (LOD) is in the range of 0.001-0.002 µg/g. The relative standard deviation RSD is less than 3% for the detection of standard mixtures at low (0.07 µg/mL), medium (3 µg/mL) and high (15 µg/mL) concentrations. A total of 12 oral care samples are studied, with the reaching concentrations of nd-0.89 µg/g for MI and nd-0.62 µg/g for MCI. Recoveries range from 95.33% to 101.43% depending on the type of sample.

Key words: isothiazolinone, parabens, cosmetics, solid phase extraction, ultra performance liquid chromatography