日用化学工业:2018,Vol.>>Issue(10):601-604
本文二维码信息
码上扫一扫!
曙红Y分光光度法测定季铵盐消毒剂的含量分析方法研究
梁勇坤,郭丽娟,王北明
(广东华润顺峰药业有限公司,广东 佛山 528300)
Study on the analytical method for determination of quaternary ammonium salt content in disinfector by eosin Y spectrophotometry
LIANG Yong-kun,GUO Li-juan,WANG Bei-ming
(Guangdong China Resources Shunfeng Pharmaceutical Co., Ltd., Foshan, Guangdong 528300, China)
摘要
图/表
参考文献
相似文献
本文已被:浏览 39次   下载 39
投稿时间:2018-05-10    
中文摘要: 建立一种紫外-可见分光光度法测定消毒剂中季铵盐含量的方法。用水溶性曙红Y与季铵盐进行显色反应,使用紫外-可见分光光度计测量其在545 nm处的吸光度。结果表明,季铵盐类消毒剂的线性范围为0.5~5.0 mg/L,相关系数均大于0.999,相对标准偏差小于5%,回收率在97.0%~107.5%之间,该方法快速、准确,适用于消毒剂中季铵盐含量的测定。
Abstract:A uv-visible spectrophotometry method for the determination of quaternary ammonium salt in disinfector was established. The color reaction was carried out with water-soluble eosin Y and quaternary ammonium salt, and the absorbance at 545 nm was measured by uv-visible spectrophotometer. The results show that the linear range of quaternary ammonium disinfector is 0.5~5.0 mg/L, the linear correlation coefficient is above 0.999, the relative standard deviation of the method is less than 5%, and the recovery rate is between 97.0% and 107.5%. The method is fast and accurate, and is suitable for the determination of quaternary ammonium salt content in disinfector.
文章编号:     中图分类号:R187;TQ423.12    文献标志码: